Model: S5735S-L24P4S-A1 Switch
Detail:
S5735S-L24P4S-A1 (24 10/100/1000BASE-T Ethernet ports, 4 Gigabit SFP, PoE+, AC power supply)
$580.00
Availability: In stock
SKU
S5735S-L24P4S-A1
Chat with ItNetworks!

S5735S-L24P4S-A1 Overview

Built on next-generation, high-performance hardware and powered by Huawei’s Versatile Routing Platform (VRP), CloudEngine S5735-L switches feature flexible Ethernet networking, diversified security control, and support for multiple Layer 3 routing protocols — providing higher performance and more powerful service processing capabilities for networks.

Quick Spec

Table 1 shows the quick spec.

Product Model

S5735S-L24P4S-A1

Memory

512 MB

Flash memory

512 MB

Typical power consumption [W]

41.7 W

MTTR [hour]

2 hour

 

S5735S-L24P4S-A1 Specification

S5735S-L24P4S-A1 Specification

Typical power consumption [W]

41.7 W

Typical heat dissipation [BTU/hour]

142.29 BTU/hour

Maximum power consumption [W]

·         Not providing the PoE function: 53.2 W

100% PoE loads: 433.2 W (PoE: 380 W)

Maximum heat dissipation [BTU/hour]

·         Not providing the PoE function: 181.52

100% PoE loads: 1478.12

MTBF [year]

55.72 year

MTTR [hour]

2 hour

Availability

>0.99999

Noise at normal temperature (acoustic power) [dB(A)]

50 dB(A)

Noise at normal temperature (acoustic pressure) [dB(A)]

38.2 dB(A)

Number of card slots

0

Number of power slots

0

Number of fans modules

2

Redundant power supply

Not supported

Long-term operating temperature [°C(°F)]

-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)

Short-term operating temperature [°C(°F)]

-5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.)

Restriction on the operating temperature variation rate [°C(°F)]

When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:

·         The equipment operates at a temperature of over 50°C (122°F) consecutively for at most 96 hours in one year.

·         The equipment operates at a temperature of over 50°C (122°F) for a total of no more than 360 hours in one year.

·         The equipment operates at a temperature of over 50°C (122°F) for no more in 15 times in one year.

The equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.

The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.

Storage temperature [°C(°F)]

-40°C to +70°C (-40°F to +158°F)

Long-term operating relative humidity [RH]

5% to 95%, noncondensing

Long-term operating altitude [m(ft.)]

0-5000 m (0-16404 ft.)

Storage altitude [m(ft.)]

0-5000 m (0-16404 ft.)

Power supply mode

AC built-in

Rated input voltage [V]

·         AC input: 100 V AC to 240 V AC, 50/60 Hz

High-Voltage DC input: 240 V DC

Input voltage range [V]

·         AC input: 90 V AC to 290 V AC, 45 Hz to 65 Hz

High-Voltage DC input: 190 V DC to 290 V DC

Maximum input current [A]

6 A

Memory

512 MB

Flash memory

512 MB

Console port

RJ45

Eth Management port

Not supported

USB

Not supported

RTC

Not supported

RPS input

Not supported

Service port surge protection [kV]

Common mode: ±7 kV

Power supply surge protection [kV]

±6 kV in differential mode, ±6 kV in common mode

Types of fans

Built-in

Heat dissipation mode

Heat dissipation with fan, intelligent fan speed adjustment

Airflow direction

Air intake from left and front, air exhaustion from right

PoE

Supported

Certification

EMC certification

Safety certification

Manufacturing certification