PWR-C1-440WDC=
Model: | Cisco Switch Power Supply 440W DC |
Detail: |
440W DC Config 1 Power Supply
|
Product Code |
PWR-C1-440WDC |
Power supply rated maximum |
440W |
Total output BTU (Note: 1000 BTU/hr = 293W) |
1517BTU/hr, 440W |
Input-voltage range and frequency |
-36VDC to -72VDC |
Input current |
<8A at -72VDC <16A at -36VDC |
Output ratings |
-56V at 7.86A |
Output holdup time |
> 2ms at -48VDC |
Power-supply input receptacles |
Terminal strip |
Power cord rating |
20A at 100VDC |
Physical specifications |
(H x W x D): 1.58 X 3.25 X 12.20 in |
PWR-C1-440WDC Specification
PWR-C1-440WDC Specification |
|
Power supply rated maximum |
440W |
Total output BTU (Note: 1000 BTU/hr = 293W) |
1517BTU/hr, 440W |
Input-voltage range and frequency |
-36VDC to -72VDC |
Input current |
<8A at -72VDC <16A at -36VDC |
Output ratings |
-56V at 7.86A |
Output holdup time |
> 2ms at -48VDC |
Power-supply input receptacles |
Terminal strip |
Power cord rating |
20A at 100VDC |
Physical specifications |
(H x W x D): 1.58 X 3.25 X 12.20 in |
Operating temperature |
23 to 113°F (-5 to 45°C) |
Storage temperature |
-40 to 158°F (-40 to 70°C) |
Relative humidity operating and nonoperating noncondensing |
5 to 90% noncondensing |
Altitude |
10,000 ft. (3000 meters), up to 45°C |
MTBF |
Calculated MTBF must be greater than 300,000 using Telcordia SR-332, Method 1, Case 3. Demonstrated MTBF is 500,000 hr (with 90% confidence level). |
EMI and EMC compliance |
FCC Part 15 (CFR 47) Class A ICES-003 Class A EN 55022 Class A CISPR 22 Class A AS/NZS 3548 Class A BSMI Class A (AC input models only) VCCI Class A EN 55024, EN300386, EN 50082-1, EN 61000-3-2, EN 61000-3-3 EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN 61000-6-1 |
Safety compliance |
UL 60950-1, CAN/CSA-C22.2 No. 60950-1, EN 60950-1, IEC 60950-1, CCC, CE Marking |
LED indicators |
“AC OK”: Input power to the power supply is OK “PS OK”: Output power from the power supply is OK |